The SPHERO™ Calibration Particles are designed for routine calibration of flow cytometers. By using these particles, the sensitivity and linearity of the system can be determined. The sensitivity of the instrument will help detect any dye or light contamination. The linearity of the instrument will determine if the logarithmic amps and PMTs are functioning properly.

SPHERO™ Rainbow Calibration Particles

– Contains a mixture of fluorophores that enable the Rainbow Calibration Particles to be excited at any wavelength from 365 nm to 650 nm
– Allows the calibration of the FITC, PE, PE-TR, PE-Cy5, and APC channels in the flow cytometer with the same set of particles
– Consists of set of several similar size particles with different fluorescence intensities in a convenient dropper bottle

Catalog No.DescriptionConcentrationNominal DiameterSize
RCP-05-5Rainbow Calibration Particles, 4 peaks107/mL0.4-0.6 µm5 mL
RCP-20-5Rainbow Calibration Particles, 4 peaks107/mL1.8-2.2 µm5 mL
RCP-30-5 (6 peaks)Rainbow Calibration Particles, 6 peaks107/mL3.0-3.4 µm5 mL
RCP-30-5A (8 peaks)Rainbow Calibration Particles, 8 peaks107/mL3.0-3.4 µm5 mL
RCP-30-5A (Euroflow)Rainbow Calibration Particles, 8 peaks, (Euroflow)
this item is for the Euroflow Group
107/mL3.0-3.4 µm5 mL
RCP-30-20ARainbow Calibration Particles, 8 peaks107/mL3.0-3.4 µm20 mL
RCP-30-5A-2Rainbow Calibration Particles, 2nd peak from the 8 peak set
other single peak is also available, get the quota from HyperCyte
107/mL3.0-3.4 µm5 mL
RCP-32-5Rainbow Calibration Particles, 6 peaks107/mL3.2 (+/- 0.1) µm5 mL
RCP-35-5Rainbow Calibration Particles, 4 peaks107/mL3.5-4.0 µm5 mL
RCP-60-5Rainbow Calibration Particles, 6 peaks107/mL6.0-6.4 µm5 mL
RCP-60-20Rainbow Calibration Particles, 6 peaks107/mL6.0-6.4 µm20 mL
RQC-30-5Rainbow QC Calibration Particles, 3 peaks2×107/mL3.0-3.4 µm5 mL

SPHERO™ Ultra Rainbow Calibration Particles

– Designed for routine calibration of the flow cytometer in all channels
– Contain a mixture of fluorophores that enable the optimization of linearity, sensitivity, and resolution of the flow cytometer
– Especially useful in the Far Red and Violet channels

Catalog No.DescriptionConcentrationNominal DiameterSize
URCP-38-2KUltra Rainbow Calibration Kit, 6 peaks
(Blank, 2×106/mL), (Fluorescent Particles, 107/mL)
107/mL after mixing3.8 µm (+/- 0.2 µm)1×3 mL
1×2 mL
URCP-38-20KUltra Rainbow Calibration Kit, 6 peaks
(Blank, 2×106/mL), (Fluorescent Particles, 107/mL)
107/mL after mixing3.8 µm (+/- 0.2 µm)1×30 mL
1×20 mL
URCP-50-2KUltra Rainbow Calibration Kit, 6 peaks
(Blank 2×106/mL), (Fluorescent Particles 107/mL)
107/mL after mixing5.0-5.4 µm1×3 mL
1×2 mL
URCP01-30-10KUltra Rainbow Calibration Particle Kit, 3 peaks106/mL3.0-3.4 µm10×3 mL
URCP-100-2Ultra Rainbow Calibration Particles, 6 peaks107/mL8.0-12.9 µm2 mL
URCP-100-2HUltra Rainbow Calibration Particles, 9 peaks107/mL8.0-12.9 µm2 mL
URCP-100-6KUltra Rainbow Calibration Kit, 6 peaks107/mL after mixing8.0-12.9 µm6×2 mL